TAIHEI Pressure Switch
TAIHEI BOEKI
Pressure Switches Super Z Series
Bellows Actuated
Unit : MPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
♣ Norminal
Pressure |
Proof
Pressure |
SZ001B |
SZ001BW |
0.003 - 0.1 |
0.003 - 0.2 |
0.004 - 0.02 |
0.1 |
0.15 |
SZ002B |
SZ002BW |
0.005 - 0.2 |
0.005 - 0.04 |
0.008 - 0.04 |
0.2 |
0.3 |
SZ006B |
SZ006BW |
0.005 - 0.6 |
0.02 - 0.1 |
0.03 - 0.1 |
0.6 |
0.9 |
SZ010B |
SZ010BW |
0.005 - 1 |
0.04 - 0.2 |
0.05 - 0.2 |
1 |
2 |
SZ025B |
SZ025BW |
0.03 - 2.5 |
0.1 - 0.5 |
0.13 - 0.5 |
2.5 |
4.2 |
SZ035B |
SZ035BW |
0.05 - 3.5 |
0.15 - 0.8 |
0.19 - 0.8 |
3.5 |
5.3 |
SZ050B |
SZ050BW |
0.1 - 5 |
0.35 - 0.9 |
0.45 - 0.9 |
5 |
14 |
SZ115B |
SZ115BW |
0.2 - 11.5 |
0.8 - 1.8 |
1 - 1.8 |
11.5 |
17.5 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Pressure Switches Super Z Series
Piston Actuated
Unit : MPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
Proof
Pressure |
SZ032P |
SZ032PW |
0.1 - 3.2 |
0.18 - 0.6 |
0.22 - 0.6 |
10 |
SZ070P |
SZ070PW |
0.2 - 7 |
0.28 - 1.3 |
0.34 - 1.3 |
35 |
SZ210P |
SZ210PW |
0.5 - 20.5 |
0.7 - 3.8 |
0.85 - 3.8 |
70 |
SZ400P |
SZ400PW |
1 - 40 |
1.5 - 7.5 |
1.8 - 7.5 |
70 |
SZ635P |
SZ635W |
2 - 63.5 |
2.5 - 12 |
3 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches Super Z Series
Differential Pressure Switches
Bellows & Piston Actuated
Unit : MPa
Type |
Actuator |
Working Pressure
Range |
♥ Sensitivity |
♠ Operating
Pressure Diff. |
Norminal
Pressure |
Proof
Pressure |
SZ-01BSD |
Bellows |
0.0027vac - 0.1vac
(20 - 760mmHgV) |
0.0067vac - 0.033vac |
0 - 0.067vac |
0.1 |
0.15 |
SZ002BD |
Bellows |
0.005 - 0.2 |
0.005 - 0.04 |
0 - 0.2 |
0.2 |
0.3 |
SZ006BD |
Bellows |
0.005 - 0.6 |
0.02 - 0.1 |
0 - 0.6 |
0.6 |
0.9 |
SZ010BD |
Bellows |
0.005 - 1 |
0.04 - 0.2 |
0 - 1 |
1 |
2 |
SZ025BD |
Bellows |
0.03 - 2.5 |
0.14 - 0.5 |
0 - 2.5 |
2.5 |
4.2 |
SZ070PD |
Piston |
0.2 - 7 |
0.3 - 1.3 |
0 - 7 |
- |
35 |
SZ210PD |
Piston |
0.5 - 20.5 |
0.7 - 3.8 |
0 - 20.5 |
- |
70 |
♥ Sensitivity is a pressure difference between switch trip and reset point.
♠ Differential is a pressure difference between a high pressure actuator and a low pressure actiator, and must always be Hp. > Lp.
Pressure Switches Super Z Series
Vacuum Switch
Bellows Actuated
Unit : kPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband |
Proof Pressure |
SZ-01BSV |
2.7vac - 100vac |
3.3vac - 33vac |
150 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches Super Z Series
Special Pressure Switches
Bellows Actuated
Unit : kPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
♣ Norminal
Pressure |
Proof
Pressure |
SZ001BR |
SZ001BRW |
80vac - 100 |
9 - 40 |
10 - 40 |
100vac - 100 |
300 |
SZ005BR |
SZ005BRW |
73vac - 500 |
20 - 100 |
30 - 100 |
100vac - 500 |
900 |
SZ009BR |
SZ009BRW |
67vac - 900 |
40 - 200 |
50 - 200 |
100vac - 900 |
2000 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Pressure Switches Super Z Series
Diaphragm Actuated
Unit : kPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
Norminal
Pressure |
Proof
Pressure |
SZ1/4D |
SZ1/4DW |
3 - 15 |
1.5 - 9 |
2 - 9 |
0 - 25 |
300 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches Z Series
Diaphragm Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TCZ-5 |
0.005 - 0.52 |
0.02 - 0.1 |
0.02 - 0.11 |
0.03 - 0.12 |
1.8 |
TCZ-1 |
0.005 - 1 |
0.03 - 0.2 |
0.04 - 0.21 |
0.05 - 0.22 |
3 |
TCZ-2 |
0.02 - 1.8 |
0.08 - 0.39 |
0.08 - 0.4 |
0.12 - 0.42 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches Z Series
Piston Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TDZ-1 |
0.1 - 3.2 |
0.2 - 0.7 |
0.2 - 0.7 |
0.25 - 0.8 |
10 |
TDZ-3 |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TDZ-4 |
0.5 - 20.5 |
0.06 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TDZ-7 |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDZ-8 |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
TDZ-13 |
0.2 - 3.5 |
0.25 - 1.3 |
0.3 - 1.4 |
0.35 - 1.5 |
35 |
TDZ-34 |
0.5 - 10 |
0.6 - 3.8 |
0.7 - 3.8 |
1.2 - 4 |
70 |
TDZ-47 |
1 - 20 |
1.4 - 7.5 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDZ-78 |
2 - 30 |
2 - 11 |
2.5 - 12 |
3.5 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches V Series
Diaphragm Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TCV-5 |
0.005 - 0.52 |
0.02 - 0.1 |
0.02 - 0.11 |
0.03 - 0.12 |
1.8 |
TCV-1 |
0.005 - 1 |
0.03 - 0.2 |
0.04 - 0.21 |
0.05 - 0.22 |
3 |
TCV-2 |
0.02 - 1.8 |
0.08 - 0.39 |
0.08 - 0.4 |
0.12 - 0.42 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Pressure Switches V Series
Piston Actuated
Unit : MPa
Type |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TDV-1 |
0.1 - 3.2 |
0.2 - 0.7 |
0.2 - 0.7 |
0.25 - 0.8 |
10 |
TDV-3 |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TDV-4 |
0.5 - 20.5 |
0.06 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TDV-7 |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TDV-8 |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Explosion Proof Pressure Switches TEX-SZ Series
Bellows Actuated
Unit : MPa
Type
SPDT DPDT |
Adjustable Range
(Decreasing Pressure) |
♠ Adjustable Deadband
SPDT DPDT |
♣ Norminal
Pressure |
Proof
Pressure |
TEX1-SZ002B |
TEXW-SZ002BW |
0.005 - 0.2 |
0.008 - 0.04 |
0.012 - 0.04 |
0.2 |
0.3 |
TEX1-SZ006B |
TEXW-SZ006BW |
0.005 - 0.6 |
0.03 - 0.1 |
0.05 - 0.1 |
0.6 |
0.9 |
TEX1-SZ010B |
TEXW-SZ010BW |
0.005 - 1 |
0.06 - 0.2 |
0.08 - 0.2 |
1 |
2 |
TEX1-SZ025B |
TEXW-SZ025BW |
0.03 - 2.5 |
0.17 - 0.5 |
0.21 - 0.5 |
2.5 |
4.2 |
TEX1-SZ050B |
TEXW-SZ050BW |
0.1 - 5 |
0.5 - 0.9 |
0.65 - 0.9 |
5 |
14 |
TEX1-SZ115B |
TEXW-SZ115BW |
0.2 - 11.5 |
1.2 - 1.8 |
1.4 - 1.8 |
11.5 |
17.5 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy
Explosion Proof Pressure Switches TEX-Z Series
Diaphragm Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z005D |
0.005 - 0.5 |
0.03 - 0.1 |
0.03 - 0.11 |
0.04 - 0.12 |
0 - 0.5 |
1.8 |
TEX1-Z010D |
0.005 - 1 |
0.04 - 0.2 |
0.05 - 0.21 |
0.1 - 0.22 |
0 - 1 |
3 |
TEX1-Z018D |
0.02 - 1.8 |
0.09 - 0.39 |
0.12 - 0.4 |
0.2 - 0.42 |
0 - 1.8 |
4 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Piston Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband
Low Range Mid. Range High Range |
Proof
Pressure |
TEX1-Z032P |
0.1 - 3.2 |
0.2 - 0.16 |
0.2 - 0.6 |
0.25 - 0.7 |
10 |
TEX1-Z070P |
0.2 - 7 |
0.25 - 1.3 |
0.28 - 1.4 |
0.3 - 1.5 |
35 |
TEX1-Z210P |
0.5 - 20.5 |
0.6 - 3.8 |
0.7 - 4 |
1.2 - 4.2 |
70 |
TEX1-Z400P |
1 - 40 |
1.4 - 7.8 |
1.5 - 8 |
1.8 - 8.5 |
70 |
TEX1-Z635P |
2 - 63.5 |
2 - 11 |
2.5 - 12 |
3 - 12 |
120 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
Explosion Proof Pressure Switches TEX-Z Series
SUS316L Bellows Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z002BS |
0.005 - 0.2 |
0.008 - 0.04 |
0.2 |
0.3 |
TEX1-Z006BS |
0.005 - 0.6 |
0.03 - 0.1 |
0.6 |
0.9 |
TEX1-Z010BS |
0.005 - 1 |
0.06 - 0.2 |
1 |
2 |
TEX1-Z025BS |
0.03 - 2.5 |
0.17 - 0.5 |
2.5 |
4.2 |
TEX1-Z050BS |
0.1 - 5 |
0.5 - 0.9 |
5 |
14 |
TEX1-Z115BS |
0.2 - 11.5 |
1.2 - 1.8 |
11.5 |
17.5 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Special Diaphragm Actuated
Unit : kPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z1/4D |
3 - 25 |
2.5 - 8 |
0 - 25 |
300 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy.
Explosion Proof Pressure Switches TEX-Z Series
Special & Vacuum - Bellows Actuated
Unit : MPa
Type |
Adjustable Range |
♠ Adjustable Deadband |
♣ Nominal
Pressure |
Proof
Pressure |
TEX1-Z001BR |
80vac - 100 |
10 - 40 |
100vac - 100 |
300 |
TEX1-Z005BR |
73vac - 500 |
20 - 100 |
100vac - 500 |
900 |
TEX1-Z009BR |
67vac - 900 |
40 - 200 |
100 vac - 900 |
2000 |
♠ Adjustable Deadband : Add to range to obtain an upper actuation Point.
♣ Norminal Pressure : Pressure applied continuously to bellows should be less than Rating Pressure for best lift expectancy. |